fluke 1625 earth ground tester user manual

1 post / 0 new
xnnrjit
Картинка користувача xnnrjit.
fluke 1625 earth ground tester user manual

fluke 1625 earth ground tester user manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:fluke 1625 earth ground tester user manual.pdf
Size: 4374 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 13 May 2019, 19:56 PM
Rating: 4.6/5 from 625 votes.

Status: AVAILABLE

Last checked: 16 Minutes ago!

In order to read or download fluke 1625 earth ground tester user manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

fluke 1625 earth ground tester user manualHeavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments. Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.Minimal current in single branch to be measured 0.5 mA With transformer (1000:1) 0.1 mA With transformer (200:1) Max. Automatic range selection. The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified. Models: Fluke 1625-2 GEO Earth Ground Tester Kit Fluke 1625-2 Kit Fluke 1625-2 GEO Earth Ground Tester Kit Includes: GEO Earth Ground Tester User’s Manual Batteries Quick Reference Guide USB Cable 2 Clamps C1620 Professional Carrying Case 4 Earth Ground Stakes 3 Cable Reels Reviews: Fluke 1625-2 GEO Earth Ground Tester Kit Rated 4 out of 5 by mhieron from Very well put together Kit Purchased this kit to start new program at Hydro plants. Kit has everything you need. Very straightforward to use and results easy to interpret. World class accessories speed set up and test time. World class accessories will simplify and speed up testing time. All rights reserved. Specifications are subject to change without notice. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods. The 1625-2 provides the perfect solution by combining the latest technology into a compact, field-rugged instrument.http://acilperde.com/userfiles/fiat-bravo-97-manual.xml

    Tags:
  • fluke 1625 earth ground tester user manual, fluke 1625 earth ground tester manual, fluke 1625 advanced earth ground tester manual, fluke 1625-2 earth ground tester manual, fluke 1625 earth ground tester user manual, fluke 1625 earth ground tester user manual pdf, fluke 1625 earth ground tester user manual instructions, fluke 1625 earth ground tester user manual user, fluke 1625 earth ground tester user manual diagram, fluke 1625 earth ground tester user manual.

Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information. Storage If the Tester is stored for an extended period of time or is not in use for a long time, you. EE PROM memory Contact service. Four push buttons start measurements, read out supplementary measurement values, and select special functions. See Table 6 for more information. Measurement values are shown on a liquid crystal display with units. Additional special characters indicate measurement mode, operating condition and error messages. Return to the standard operation mode by pressing any button or turning of the central rotary switch.A specific description of the different applications is given further on in this manual. Now a fully automated test sequence of all relevant parameters like auxiliary earth electrode and probe and earth electrode resistance is implemented and finished with the display of the result R 1. Read out measured value R 2. One part flows via pylon construction to the overhead earth wire and further to the parallel circuited pylon earthing resistances. Measuring process: Auxiliary earth Earth electrode electrode edw019.eps Figure 10. National Bureau of Standards, Bulletin 12 (4), Paper 258, S 478-496;. The respectively higher measured value is displayed first. This feature enables the operator to create an instrument setup with customer defined settings according to the specific need. Any three-digit number can be entered. Include a brief description of the problem. Fluke assumes NO responsibility for damage in transit. Printed in USA Printed in USA All product names are trademarks of their respective companies. The 1625 provides the perfect solution by combining the latest technology into a compact, field-rugged and extremely easy to use instrument. For stakeless earth resistance measurements, the EI-1625 must be purchased. (The EI-1625 comes standard with the 1625 Kit).http://christianhohmann.com/userfiles/fiat-bravo-manuals-download.xml Refer to Appendix A for a complete set of operating information including specifications. In addition, use of this equipment requires compli- ance with the legal and safety instructions pertaining to the specific application in question. This device has been developed, designed and manufactured in compliance with quality system DIN ISO 9001.The frequency can be selected manually or automatically (AFC). Via microprocessor, a drop in battery capacity down to typ. 10 of its specified value is indicated on the display with symbol LO-BAT. F Display unit, liquid crystal digits, 18 mm high with automatic decimal point as well as active illumination. According to the selected measuring function, different setting values can be displayed and changed in the control loop.If the value stays the same, the distance is sufficient. If the measured value changes, probe or auxil- iary earth electrode must be repositioned until the measured value R stays constant. Now a fully automated test sequence of all relevant parameters like auxiliary earth electrode, probe- and earth electrode resistance, is implemented and fin- ished with the display of the result R 1. Nevertheless, to get reliable values, the instrument offers the possibility of averanging over a longer period. Curve 3: With increasing depth E is not decreasing: a strip conductor elec- trode is advisable. For measurements of very low resistances a compensation of the connecting leads is suggested (see “Compensation of Measuring Lead Resistance”). Note If the limit values required by regulations are changed incorrect, er- roneous test results may be displayed. All consump- measured tion values edw027.eps remain stored No or Apart from incorrect voltage. Avoid aggressive cleaning agents and solvents (trilene, chlorothene etc.). Service work must only be undertaken by trained qualified staff.http://seasailing.us/node/3285 In all repair work care must be taken that the design parameters of the instru- ment are not modified to the detriment of safety, that assembled parts corre- spond to the original spares and that they are reassembled properly (factory state). Include a brief description of the problem. To locate an authorized service center, call Fluke using any of the phone num- bers listed below: USA: 1-888-99-FLUKE (1-888-993-5853) The use of ground stakes is not necessary. Before this method was available, users were required to disconnect an indi- vidual ground path to be tested from other grounds to eliminate the influence of parallel ground paths. EI-1625) All information contained in this section exclusively refers to this application. Principle: Ground testing without using earth stakes for the probe and the auxiliary earth elec- trode. Settings on the Tester Refer to the Operation section in the Testers instruction manual. The rotary switch of the tester must be in the R 3 pole position. This wire is not only ohmic. For calculation of the short circuit current this impedance at line frequency has to be determined. World class accessories speed set up and test time. With internal memory storage of up to 1500 records, accessible via USB port for rapid data transfer and viewing of results. The earth ground tester also gives you world class accessories that take the tedium out of earth ground testing. New wire reels speed up setup and tear down time as much as 50. Heavy duty stakes can be hammered into dry, hard soil. And new colour-coded wires make setup simple and help eliminate mistakes.The 1625-2 offers automatic frequency control (AFC) which helps identify existing interference and chooses a measurement frequency to minimize it's effect. While also offering adjustable limits for quicker testing.With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by the clamp and the current is measured using the second clamp. The 1625-2 then automatically determines the resistance of the earth ground rod. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you've not considered before: inside buildings, power pylons or anywhere you don't have access to soil. You can unsubscribe at any time. Therefore, you must select at least one lens with this item. For the best experience on our site, be sure to turn on Javascript in your browser. It's a distinctive earth ground tester that can perform all four types of earth ground measurement.The Earth Ground Tester is able to measure earth ground loop resistances using only clamps. Fluke 1625-2 Geo Earth Ground Tester Kit Features Stakeless Testing The Fluke 1625-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall of Potential test method must be used. With Stakeless testing, the earth ground rod does not need to be disconnected - leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil. Minimal current in single branch to be measured 0.5 mA With transformer (1000:1) 0.1 mA With transformer (200:1) Max. SECURE CHECKOUT ABOUT US Mektronics is Australia’s leading supplier of quality tools and equipment. We proudly represent and support many of the world's premium brands- all of which can be found in this site. With over 50 years of experience within the industry our sales team have unsurpassed industry and product knowledge and are happy to assist with any queries you may have. A good grounding system will improve the reliability of your equipment and reduce the likelihood of damage due to lightning or fault currents. Billions are lost each year in the workplace due to electrical fires. This does not account for related litigation costs and loss of personal and corporate productivity. What are the methods of earth ground testing. There are four types of earth ground testing methods available: Soil Resistivity (using stakes) Fall-of-Potential (using stakes) Selective (using 1 clamp and stakes) Stakeless (using clamps only) FLUKE 1625 Key Features: The FLUKE 1625-2 is distinctive earth ground tester that can perform all four types of earth ground measurement: 3- and 4-Pole Fall of Potential (using stakes) 4-Pole Soil Resistivity testing (using stakes) Selective testing (using 1 clamp and stakes) Stakeless testing (using 2 clamps only) The FLUKE 1625-2 tester is also easy to use and for each test, the tester informs you which stakes or clamps are needed to be connected, plus the large rotary switch can be used even with a gloved hand. The FLUKE 1625-2 Earth Ground Tester can measure earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. This allows you to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil. If a bonded earth ground system does not exist for the building or structure under test, and there is only one path to ground, you can use the 1625-2 to perform the fall-of-potential test method with stakes. Unboxing the FLUKE 1625: What comes with the FLUKE 1625.Maximise your return on investment with product and software training modules. A lack of product training can result in under-utilisation of test equipment, low return on investment and, most importantly, incorrect use.Maximise your return on investment with product and software training modules. A lack of product training can result in under-utilisation of test equipment, low return on investment and, most importantly, incorrect use. Extended until the end of August.Acutest Direct trading name of UK Test Instruments Ltd Registered in England and Wales Number 2529960 VAT Number GB 927 2027 36. Prices Ex VAT. Terms and Conditions Apply.Including everything professional earth testers will need for testing in a wide variety of applications, this kit is a must-have. Automatic range selection. The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified. Company No: 4457106. VAT Registration: GB779714081. EW-20047-01 Ensure proper grounding and eliminate equipment failure. Click on the calibration service to view details, then order. Kits add on: two clamps, four earth ground stakes, three color-coded cable reels, and carrying case. Units aid in establishing and troubleshooting effective grounding systems, for both equipment and structures, and eliminate instrument errors in electrical devices as well as harmonic distortion issues and power factor problems to keep your systems running and operators safe. These units perform all four essential earth ground tests including three- and four-pole fall of potential, four-pole soil resistivity, one clamp selective, and two clamp stakeless earth ground tests. Both are essential for technicians, electrical contractors, and industrial electricians for gas, telecom, utility, and manufacturing applications. Our specialists are here to help you find the best product or part available for your application. Call or Email us and we will make sure you get the right product or part for the job.All Rights Reserved. Terms of Use Privacy Policy Site Map Other Site Maps go BACK TO TOP. Instruction manualThe Fluke 1625-2 GEO Earth Ground Tester offers data storage (up to 1500 GEO Earth Ground Tester; User's Manual; Batteries; Quick Reference Guide; USB The Fluke 1625-2 earth ground tester is able to measure earth ground loop Measuring frequency, 94, 105, 111, 128 Hz selected manually or automatic. Fluke 1625 GEO Earth Ground Testers Formaly the LEM Saturn Geo and 6 - AA LR6 Batteries; 2 - Measuring leads 1.5 m; 2 - Alligator Clips; 1 - Users Manual. General with wire, 2 clamps, batteries, and manual—all inside a rugged Fluke carrying case. The Fluke 1625-2 improves your earth ground testing process with: GEO Earth Ground Tester; User's Manual; Batteries; Quick Reference Guide; USB Cable. Each Fluke product is warranted to be free from defects in material and. The 1625-2 Earth Ground Tester (Tester or Product) is a compact, field-rugged. Use Peatix for any event and ticketing needs! Co-organizers can edit group and event pages, access sales and attendee information, manage ticket sales and more. It has the added benefit being able to conduct selective analysis and automatic frequency control. This in turn allows for a much more accurate ground value. Reliable delivery with tracking and signature upon receiving your item - unless otherwise notified. Please see our Deliveries page for a full state-by-state guide. Returns We stand by the products we sell, which is why we offer a 100 money back guarantee for up to 7 days from receiving your item. See how we stand by Our Guarantee. Our payment security system encrypts your information during transmission. We don’t share your credit card details with third-party sellers, and we don’t sell your information to others. You may be charged a restocking fee up to 50 of item's price for used or damaged returns and up to 100 for materially different item.Please try again.Please try again.In order to navigate out of this carousel please use your heading shortcut key to navigate to the next or previous heading. In order to navigate out of this carousel please use your heading shortcut key to navigate to the next or previous heading. Register a free business account Please try your search again later.The simple “stakeless” method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test. The Fluke 1625 is a distinctive earth ground tester that can perform all four types of earth ground measurement. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods. The testing methods of this tester include 3 and 4 pole fall of potential which is standard earth ground testing using two ground stakes; selective testing without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp, and stakeless testing which is an innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance.Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. The Fluke 1625 GEO earth ground tester offers an innovative solution, called stakeless testing, to make your earth ground loop resistance testing quicker and easier. There is no need for a separate earth ground clamp. The Fluke 1625 features the following: 3- and 4-pole fall of potential, earth resistance loop testing, 4-pole soil resistivity testing, selective earth ground rod testing using 1 clamp, and stakeless earth ground rodtesting using 2 clamps. The 1625 has automatic frequency control (AFC) that identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value. The 1625 calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see, an also has adjustable limits for quicker testing. The tester kit includes a rugged carrying case, is IP56 rated for outdoor use and is sold one set per package. The 1625 advanced GEO earth ground tester kit is covered by a two year warranty.To calculate the overall star rating and percentage breakdown by star, we don’t use a simple average. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. It also analyzes reviews to verify trustworthiness. Click in this bar to return to normal site. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods. You may find this information useful in helping you decide whcih reviews are most helpful in making your purchasing decisions. If a review is not marked as a Verified Purchase it does not mean that the reviewer has no experience of this item as they may have one which they have acquired from elsewhere. The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified. Okay, thanks. Update my browser now With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This allows you to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil. World class accessories speed set up and test time. And the tester tells you which stakes or clamps to connect for each test. The large rotary switch and buttons are easy to operate even with a gloved hand. And you can store up to 1500 records and access them easily via the USB port. Shopify Store Design by MyWork. World class accessories speed set up and test time. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods. One specific application of this capability is quick and accurate measurement of power pylon grounds. Selective earth ground rod testing using 1 clamp. Stakeless earth ground rod testing using 2 clamps. IP56 rated for outdoor use. Rugged carrying case. USB data storage and transfer. Automatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect. Adjustable limits - for quicker testing. World class accessories speed set up and test time. For that purpose, please find our contact info in the legal notice. This tester is able to measure ground loop resistance using only clamps, this method doesn't require the use of earth ground stakes or disconnection of ground rods. Making this distinctive tester easy to use and an ideal addition to any engineers testing kit.Between September 1, 2020 and December 15, 2020 customer who purchase a Fluke product (inc. Fluke Networks) have the opportunity to claim a free product through the Fluke website with the original proof of purchase, invoice, or receipt. For each level there is a fixed range of products to claim, based on the value of the original purchase.RS definition of RoHS Compliance: RS Components has taken all reasonable steps to confirm this statement. Information relates only to products sold on or after the date of this certificate. The Manufacturers disclaim all warranties (including implied warranties of merchantability or fitness for a particular purpose) and are not liable for any damages arising from your use of or your inability to use the Information downloaded from this website. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall of Potential test method must be used. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you've not considered before: inside buildings, power pylons, or anywhere you don't have access to soil. The 1625-2 offers internal memory storage up to 1500 records, accessible via USB port for rapid data transfer and viewing of results. This earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing. And new color-coded wires make setup simple and help eliminate mistakes. Please Sign in or create an account. Something went wrong.Learn more - opens in a new window or tab This amount is subject to change until you make payment. For additional information, see the Global Shipping Program terms and conditions - opens in a new window or tab This amount is subject to change until you make payment. If you reside in an EU member state besides UK, import VAT on this purchase is not recoverable. For additional information, see the Global Shipping Program terms and conditions - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab See the seller's listing for full details. If you don't follow our item condition policy for returns, you may not receive a full refund. Refunds by law: In Australia, consumers have a legal right to obtain a refund from a business if the goods purchased are faulty, not fit for purpose or don't match the seller's description. More information at returns. Contact the seller - opens in a new window or tab and request postage to your location. Please enter a valid postcode. Please enter a number less than or equal to 1. All Rights Reserved. User Agreement, Privacy, Cookies and AdChoice Norton Secured - powered by Verisign. The 1625-2 offers internal memory storage up to 1500 records, and are accessible via the USB port for rapid data transfer and viewing of results. The Fluke 25m GR ( Green ) Earthing Cable Reel (order code 64-7157 ) and the 50m RD ( Red ) Earthing Cable Reel (order code 64-7158 ) speeds up setup and tear down time by as much as 50. The supplied heavy duty stakes can be hammered into dry, hard soil, and the colour-coded wires make setup simple and help eliminate mistakes. The Fluke 1625-2 is a unique earth ground tester that can perform all four types of earth ground measurement: 3- and 4-Pole Fall-of-Potential (using stakes) 4-Pole Soil Resistivity testing (using stakes) Selective testing (using 1 clamp and stakes) Stakeless testing (using 2 clamps only) What's in the Box. Fluke 1625-2 User's Manual 6x AA batteries Quick Reference Guide USB Cable 2 Clamps C1620 Professional Carrying Case 4 Earth Ground Stakes 3 Cable Reels. The 1625-2 features automatic frequency control and adjustable limits for quicker testing. With Stakeless testing, the earth ground rod does not need to be disconnected—leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system a major time saver. You can also perform earth ground tests in places you've not considered before: inside buildings, power pylons, or anywhere you don't have access to soil. Making this distinctive tester easy to use and an ideal addition to any engineers testing kit. Earth grounding is a connection from a circuit conductor, usually the neutral, to a ground electrode or plate placed in the earth. Equipment grounding ensures that operating equipment or a circuit is grounded properly. This prevents differences in voltage potential from a possible flash-over from things such as lightning strikes by ensuring the current finds a safe path to the earth. A ground resistance tester is able to take resistance measurements using several test methods, selective testing, stake-less testing, 2-pole testing and 3-4-pole testing. They are able to test the resistance between the earth plate or earth electrode and surrounding ground. In pole testing probes are entered in to the ground and a reading is taken at each location. Readings are then plotted against the distances, the point where the resistance drops is the approximate resistance of the grounding. This is called the fall of potential method and is highly reliable. Print Email Save Item Compare.Test Equipment pdf manual download. The Fluke 16are distinctive earth ground testers that can perform all four types of earth ground measurement.Fluke Pdf User Manuals. Shop with confidence from experts in process measurement and control instrumentation. Specifically, the Fluke testers are able to measure earth ground loop resistances using only clamps - called Stakeless testing. Fluke KIT-OB. Looking for fluke 1625 kit manual FLUKE Earth Ground Tester Kit, VAC (30JZ59). The Fluke Earth Ground Tester are able to measure earth ground loop resistances using only clamps. Fluke warrants that software will operate substantially in accordance. Free Next Day Delivery. El kit completo incluye el medidor o, cables de prueba, 4 picas de puesta a tierra, 3 rollos de cable, 2 pinzas, pilas y el manual de uso; todo dentro de un estuche de transporte profesional de Fluke. Refer to Appendix A for a complete set of. The Fluke is distinctive earth ground testers that can perform all four types of earth ground measurement. Stakeless testing is an innovative solution to make your fluke 1625 kit manual earth ground loop resistance testing quicker and easier, with no need for a separate earth ground clamp. Product details Shipping Weight: pounds (View shipping rates and policies). Test Equipment pdf manual download. This video is unavailable. Fluke 16geo earth ground testers datasheet. Test Equipment Fluke X Quick Reference Manual 10 pages. (The EI comes standard with the Kit). Register to view exclusive member pricing. Page Safety Information.Looking for FLUKE Earth Ground Tester Kit, VAC (30JZ59).